Introduction
The PCL-422 module facilitates remote mounting of the PowerSeries Neo alternate communicator outside the alarm controller cabinet.

Two PCL-422 modules are required, one mounted in the alarm controller cabinet and one in a remote cabinet with the alternate communicator.


Specifications
• Temperature range: -10°C to + 55°C (0°C to +49°C for UL/ULC listed systems)
• Relative Humidity: 93% non-condensing
• Input power: provided by compatible power supply (rated for use in conjunction with the alarm communicator). Power is routed from  the compatible power supply through the PC-Link bus to the alarm communicator
• Board current draw: 55mA
• Resettable fuse (PTC) on circuit board
• Maximum wire length from alarm panel using 22AWG: 1,000’/305m
• Power supply: HSM2300/HSM2204


Compatible Devices
Alarm Controllers: HS2016, HS2032, HS2064, HS2128
Alternate Communicators: TL280(R), 3G2080(R), TL2803G(R)
Power Supplies: HSM2300, HSM2204
Enclosures: PC5003C, PC4050CR, PC500C


Installation
The PCL-422 may be installed in the same metallic cabinet as the alarm controller/power supply (PC5003C). Internal and/or external wiring for the PCL-422 must be routed, supported, clamped or secured in a manner that reduces the likelihood of (a) excessive strain on wire and terminal connections, (b) loosening of terminal connections, and (c) damage of conductor insulation.


When installing:
• Ensure the remote mounted PCL-422 is installed on the left wall of the enclosure, as illustrated in the diagram, to allow room for the battery.
• Ensure correct orientation of the PCLink cable as shown in the diagram.


NOTE: Tamper Protection: When the PCL-422 is remotely installed with a HSM2204/2300, use the power supply tamper input to protect the
cabinet. If an additional power supply is not being used, a zone programmed as 24 hour non-latching tamper or 24 hour latching can be
used to protect the cabinet. A HSM2300/2204 power supply module is required if the RS-422 cable used exceeds 50 feet. Use the power supply’s tamper input to protect the cabinet, or use a panel zone input defined as 24 Hr latching or 24 Hr non-latching tamper zone type.